2-in-1 Transformer Testing System Low Voltage and Safety
2-in-1 Transformer Testing System Low Voltage and Safety

2-in-1 Transformer Testing System Low Voltage and Safety

MOQ : 1 Unit

2-in-1 Transformer Testing System Low Voltage and Safety Specification

  • Usage & Applications
  • Industrial
  • Frequency (MHz)
  • (200k/500k/1MHz) Megahertz (MHZ)
  • Dimension (L*W*H)
  • 435x145x500 mm Millimeter (mm)
  • Weight
  • 9-15 Kilograms (kg)
  • Warranty
  • Yes
 

2-in-1 Transformer Testing System Low Voltage and Safety Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About 2-in-1 Transformer Testing System Low Voltage and Safety

  • Low Voltage Electrical Test 
  • Hi pot/ Insulation Test
  • 20 Channels
  • Test Frequency (200k/500k/1MHz)
  • AC Voltage Output 5000V
  • DC Voltage Output 6000V
  • Insulation Resistance 12000M

SPEC

Model

2-in-1

(626X+7631)

Test Channel

20

Low Voltage Electrical Test
Model626562666267
Frequency 10Hz-200kHz10Hz-500kHz10Hz-1MHz
Frequency Resolution5 digits
Basic Accuracy0.1%
AC Drive Level10mV-2Vrms
DC Drive Level10mV-2V
Output Impedance100
Turn

Inductance or Voltage

Test Freqeuncy50Hz-200kHz

Test ModeMeter Mode / List Mode
Parameters MeasurementInductance (L)Impedance (Z)Capacitance (C)Resistance (R)Conductance (G)Susceptance (B)Admittance (Y)Alternating Current Resistance (ACR)Quality Factor (Q)Direct Current Resistance (DCR)Leakage InductanceTurn RatioBalanceShort Circuit
L, LK0.1nH ~ 9999.99H
C0.00001pF ~ 999.99mF
Q,D0.00001 ~ 99999
Z,X,R0.00001 ~ 99.9999M
Y0.01nS ~ 99.9999S
-180~ +180
DCR0.1m ~ 99.999 M
Turn0.1 ~ 99999.9 turns
Pin-Short12 pairs, between pin to pin
Hi pot/ Insulation Test
ItemsAC Hi potDC Hi potIR
Output Voltage 10V-5000V 10V-6000V 10V-1000V
Voltage Resolution 1V 1V1V 
Voltage Accuracy   
 Test Range 0.001-31mA 0.001-11mA 1-12000M
AC Arcing Detection0-200-10 -
Measuring time0.1-999s 
Ramp Time0.1-10s 
Time Resolution0.1s 
System
  ModelTransformer TesterHi pot Tester
6265/6266/62677631
  Built-in stroage128 sets15 sets
  PC Link-stroageUnlimited storage
  Power Supply

Voltage

98Vac-132Vac 195Vac-264Vac

Voltage

98Vac-132Vac 195Vac-264Vac

Frequency47-63HzFrequency47-63Hz
  Power consumption 400VA/set
  Dimension (W*H*D)344x145x343 mm (W*H*D) 435x145x500 mm (W*H*D)
  Weight9 Kg 15kg
  Interface RS-232HandlerLANUSB HostEXT. I/O RS-232RemoteUSB HostUSB DeviceEXT.I/O
  DisplaColor Screen, 7" TFT
(800*480)
Color Screen, 4.3" TFT
(480*272)
 
Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Transformer Tester and System Category

Transformer Tester 5260 Series

Transformer Tester 5260 Series

Minimum Order Quantity : 1 Unit

Warranty : Yes

Weight : 9 Kilograms (kg)

Usage & Applications : Industrial

Automatic Transformer Test system TH2840X Series

Automatic Transformer Test system TH2840X Series

Minimum Order Quantity : 1 Unit

Warranty : Yes

Weight : 11 Kilograms (kg)

Material : Metal

Usage & Applications : Industrial

Size : 430mm(W)x177mm(H)x265mm(D)

KIKUSUI  ELECTRICAL SAFETY TESTERS ;TOS9303LC,TOS5101,TOS5200,TOS5300, TOS9303,TOS9302,TOS5302,TOS5301

KIKUSUI ELECTRICAL SAFETY TESTERS ;TOS9303LC,TOS5101,TOS5200,TOS5300, TOS9303,TOS9302,TOS5302,TOS5301

Minimum Order Quantity : 1 Milliampere

Warranty : 1 Year

Material : Mild Steel

Size : Standerd



Back to top