Talk to us
08045478738
Selection
| DC Bias Current Test System | |||||||
| 6632+ Series | |||||||
| Model | 6632+6210 | 6632+6220 | 6632+6223 |
6632+6225 |
6632+6240A |
6632+6243 |
6632+6243H |
| Frequency Response | 100Hz-3MHz | 100Hz-3MHz | 100Hz-10MHz | 100Hz-30MHz | 100Hz-3MHz | 100Hz-10MHz | 100Hz-10MHz |
| Output Current Max. | 10A | 120A | 120A | 20A | 320A | 320A | 640A |
| Power consumption | 320W | 320W | 320W | 320W | 640W | 640W | 640W |
| units of the DC Bias | 1 | 6 | 6 | 1 | 8 | 8 | 16 |
| Output Current (unit) | 10A | 20A | 20A | 20A | 40A | 40A | 40A |
Replacement models: 6240A
SPEC
|
Current Accuracy |
0.000A-1.000A 1%+5mA |
| 1.001A-5.000A 2% | |
| 5.001A-40.000A 3% | |
| DCR Test | |
| Constant power output | |
| Current switch |
|
| (6632+6225 not supported) | |
| Graphic Scanning Analysis | Frequency graphic scanning analysis |
| Magnetic saturation curve (Isat) | |
| Rated current curve (Irms) |
| Model |
6632-1 6632-1S |
6632-3 6632-3S |
6632-5 6632-5S |
6632-10 6632-10S |
6632-20 6632-20S |
6632-30 6632-30S |
6632-50 6632-50S |
|
Test Frequency |
10Hz- 1MHz |
10Hz- 3MHz |
10Hz- 5MHz |
10Hz- 10MHz |
10Hz- 20MHz |
10Hz- 30MHz |
10Hz- 50MHz |
| Equivalent Circuit Analysis | 6632S | |
| Frequency Setting | Continuity | |
| Frequency Output Accuracy | ±0.01% | |
| Frequency Resolution | 100mHz, 6-bit Frequency Input | |
| Basic Accuracy | ±0.08% (typical ±0.05%) | |
| AC Drive Level | Test Signal Voltage Level |
10mV - 2Vrms(100) 10mV - 1Vrms(25) |
| Voltage Minimum Resolution | 1mV | |
| Accuracy |
ALC ON¼6¼ * Voltage ±2mV ALC OFF¼10¼ * Voltage ±2mV |
|
| Test Signal Current Level | 200µA - 20mArms | |
| Current Minimum Resolution | 10µA | |
| Accuracy |
ALC ON¼6¼ * Current ± 20µA ALC OFF¼10¼ * Current ± 20µA |
|
| DC Drive Level | 1V (fixed) | |
| Output Impedance | 25/100 (switchable) | |
| DC Bias Voltage |
Built-in ±12V (100Hz-50MHz) |
External Voltage Bias (±12V/±40V/±2000V) |
| DC Bias Current |
Option DC Bias Current Source (20A/60A/120A/320A) |
External Voltage Bias (100mA/1A) |
| Measurement Mode | Meter mode, list mode, sweep mode, and optional equivalent circuit analysis function (S model) | |
| Measurement Parameters |
|Z||Y|XRGBLDQDCRC ESRµ and ¼r |
|
| Test Time (Fastest) | < 3mS | |
| Parameters | Range |
| |Z| | 0.000 m to 9999.99 M |
| R, X | ± 0.000 m to 9999.99 M |
| |Y| | 0.00000 ¼S to 999.999 kS |
| G, B | ± 0.00000 ¼S to 999.999 kS |
| RAD | ± 0.00000 to 3.14159 |
| DEG | ± 0.000 to 180.000 |
| Cs, Cp | ± 0.00000 pF to 9999.99 F |
| Ls, Lp | ± 0.00 nH to 9999.99 kH |
| D | 0.00000 to 9999.99 |
| Q | 0.00 to 9999.99 |
| | ± 0.00% to 9999.99% |
| Rdc | 0.00 m to 99.9999 M |
| µr' µr'' | 0 to 100000 |
| ¼r' ¼r'' | 0 to 100000 |
| Measurement Circuit | Series/Parallel | |
| Correction | Open Circuit/Short Circuit/Load correction | |
| Cable Compensation | 0 / 0.5 / 1 /2 (m) | |
| BIN | ABSABS%OFF | |
| Comparator | 9 | |
| List Mode | 50 groups of Multi-steps setting (Each group contains up to 15 steps) | |
| Bulit-in Storge | 100 sets LCR setting documents, 50 groups of list mode setting | |
| USB Host Storge | LCR setting documents, list mode setting document, BMP graphics, Sweep screen and test result data | |
| Trigger Test | Auto, manual, RS-232, GPIB, Handler | |
| Power Supply | Voltage¼88-264Vac | |
| Frequency¼47-63Hz | ||
| Power consumption | 30VA | |
| Environment | Temperature¼10-40 | |
| Humidity¼20-90%RH | ||
| Dimension | DC Bias Current Source |
Impedance Analyzer |
|
(W*H*D) 356x147x497 mm/6225 356x145x644 mm/6243H/6243 356x145x525 mm/6240A 337x145x525 mm/6223 337x145x525 mm/6220 337x145x525 mm/6210 |
(W*H*D) 336x147x340 mm/6632 336x147x340 mm/6632S |
|
| Weight |
15 Kg (6225) 20 Kg (6243H/6243) 15 Kg (6223) 20 Kg (6240A) 15 Kg (6220) 15 Kg (6210) |
3.95 Kg (6632) |
| Display | - | Color Screen, 7" TFT (800*480) |
| Interface | RS-232Handler | |
Price: