  • Low Noise Precision Power Supply
  • DC ±210V/±3A DC; Pulse ±10.5A
  • 10fA/0.1¼V Output resolution (6 1/2 )
  • 1pA/10¼V measurement resolution (4 1/2)
  • 1 CH or 2 CHS
Model TH1931 TH1932
Display 7-inch touch screen 800 x 480
Key Parameters
Channels 1 2
Max Output Voltage ±210V
Current DC ±3.03A
Pulse ±10.5A
Power Supply Max Didgits 6 1/2
Resolution Voltage 0.1¼V
Current 0.01pA
Measurement Max Didgits 4 1/2
Resolution Voltage 10¼V
Current 1pA
Voltage Range 0.2V-200V
Min. Interval Time 1¼s
Voltage Output
Range Resolution Accuracy ± (% of reading + bias)

DC output voltage or

pulse peak/base voltage

Max. Current 1 Pulse Width 2
DC Output Pulse Output
0.2V 100nV ±(0.015%+225¼V) 0|V|0.21V ±3.03A ±3.03A 50¼sttmax
±10.5A 50¼st1ms
2V 1¼V ±(0.015%+225¼V) 0|V|2.1V ±3.03A 50¼sttmax
±10.5A 50¼st1ms
20V 10¼V ±(0.015%+5mV) 0|V|6V ±3.03A 50¼sttmax
±10.5A 50¼st1ms
0|V|21V ±1.515A ±1.515A 50¼sttmax
200V 100¼V ±(0.015%+50mV) 0|V|6V ±3.03A ±3.03A 50¼sttmax
±10.5A 50¼st1ms
0|V|21V ±1.515A ±1.515A 50¼sttmax
0|V|180V  ±1.05A 50¼st10ms 
0|V|200V  ±1.515A 50¼st2.5ms
0|V|210V ±105mA ±105mA 50¼sttmax
Note¼
1 Refer to the Limits table section when using channels 1 and 2 for DC outputs or pulsed outputs (50 ¼s <= t<= tmax (= 99.9999ks)).
2 For pulses with 50¼s<=t<=tmax, the maximum duty cycle is 99.9999%.
For pulses with 50¼s<=t<=1ms, 50¼s<=t<=2.5ms or 50¼s<=t<=10ms, the maximum duty cycle is 2.5%.
Current Output
Range    Setting Resolution Accuracy ± (% of reading + bias) DC output current or pulse peak/base current1 2 Max. Voltage Pulse Widtht3
DC Output Pulse Output
10nA 10fA ±(0.10%+50pA) 0|I|10.5nA ±210V ±210V 50¼sttmax
100nA 100fA ±(0.06%+100pA) 0|I|105nA
1¼A 1pA ±(0.025%+500pA) 0|I|1.05¼A
10¼A 10pA ±(0.025%+1.5nA) 0|I|10.5¼A
100¼A 100pA ±(0.02%+25nA) 0|I|105¼A
1mA 1nA ±(0.02%+200nA) 0|I|1.05mA
10mA 10nA ±(0.02%+2.5¼A) 0|I|10.5mA
100mA 100nA ±(0.02%+20¼A) 0|I|105mA
1A 1¼A ±(0.03%+1.5mA) 0|I|105mA
105mA|I|1.05A ±21V ±21V
0|I|1.05A  ±200V 50¼st2.5ms
 ±180V 50¼st10ms
1.5A ±(0.05%+3.5mA) 0|I|105mA ±210V ±210V 50¼sttmax
105mA|I|1.515A ±21V ±21V
0|I|1.515A  ±200V 50¼st2.5ms
0|I|1.05A  ±180V 50¼st10ms
3A 10¼A ±(0.4%+7mA) 0|I|105mA ±210V ±210V 50¼sttmax
105mA|I|1.515A ±21V ±21V
1.515A|I|3.03A ±6V ±6V
10A 4 ±(0.4%+25mA)5 0|I|10.5A  ±6V 50¼st1ms
0|I|1.515A  ±200V 50¼st2.5ms
0|I|1.05A  ±180V 50¼st10ms
»Note¼
1 Refer to the Limits table section when using channels 1 and 2 for DC outputs or pulsed outputs (50 ¼s <= t <= tmax (= 99.9999ks)).
2 The maximum base current is 500mA for pulses with 50¼s<=t<=1ms, and the maximum base current is 50mA for pulses with 50¼s<=t<=2.5ms or 50¼s<=t<=10ms.
3 The maximum duty cycle is 99.9999% for pulses with 50 ¼s <= t <=tmax and the maximum duty cycle is 2.5% for pulses with 50 ¼s <= t <=1 ms, 50 ¼s <= t <= 2.5 ms or 50 ¼s <= t <= 10 ms.
4 10A range for pulse mode only, not for DC mode.
5  Measurement speed is 0.01 PLC.

 

Range Voltage Measurement Resolution Accuracy
0.2V 0|V|0.212V 10¼V ±(0.015% + 225¼V)
2V 0|V|2.12V 100¼V ±(0.02% + 350¼V)
20V 0|V|21.2V 1mV ±(0.015% + 5mV)
200V 0|V|212V 10mV ±(0.015% + 50mV)
Current Measurement
Range Current Measurement Resolution Accuracy
10nA 0|I|10.6nA 1pA ±(0.10 % + 50pA)
100nA 0|I|106nA 10pA ±(0.06% + 100pA)
1¼A 0|I|1.06¼A 100pA ±(0.025% + 500pA)
10¼A 0|I|10.6¼A 1nA ±(0.025% + 1.5nA)
100¼A 0|I|106¼A 10nA ±(0.02% + 25nA)
1mA 0|I|1.06mA 100nA ±(0.02% + 200nA)
10mA 0|I|10.6mA 1¼A ±(0.02% + 2.5¼A)
100mA 0|I|106mA 10¼A ±(0.02% + 20¼A)
1A 0|I|1.06A 100¼A ±(0.03% + 1.5mA)
1.5A 0|I|1.53A ±(0.05% + 3.5mA)
3A 0|I|3.06A 1mA ±(0.4% + 7mA)
10A1 0|I|10.6A ±(0.4% + 25mA)
»Note¼
1 For pulse mode, not for DC mode.
Pulse source (pulse width is the time from 10% rising edge to 90% falling edge, base level: pulse low level, peak level: pulse high level)
Minimum programmable pulse width 50¼s
Pulse width programming resolution 1¼s
Interface RS232C, USB HOST, USB DEVICE, LAN, HANDLER
Environment & Temperature
Environment Suitable for indoor equipment
Temperature of operating condition 0C - 55C
Humidity of operating condition 30% - 80% RH¼Ë†non-condensing¼
Elevation of operating condition 0 - 2000 meters¼Ë†6561ft¼
Temperature of storage condition 30C - +70C
Humidity of storage condition 10% - 90% RH¼Ë†non-condensing¼
Elevation of storage condition 0 - 4600 meters¼Ë†15092ft¼
Warm-up time after power on 60minutes
General Indicator
Power supply 90 V to 264V,47 Hz to 63Hz, maximum
Power consumption ¼“250VA
Rack mount 215mmx132mmx490mm
Dimension 235mmx154mmx530mm
Weight Approx. 8.5kg (single)/10kg (dual)
Safety Class I Safety
EMC standards IEC61326-1/EN61326-1
AS/NZS CISPR 11
Insulation resistance Under the reference working conditions, the insulation resistance between the power terminals and the shell is not less than 50M;
Under humid and hot transportation conditions, the insulation resistance  between the power terminals and the shell is not less than 2M.
Dielectric strength Under the reference working conditions, the power terminals and the shell can withstand the rated voltage of 1.5kV, frequency of 50Hz AC voltage for 1 minute, without breakdown and šying arc phenomenon.
Leakage current 3.5mA
Safety certification CE, cCSA¼s, C-Tick

 